GHL pH Probe – ProfiLux Aquarium Sensor
DescriptionThe GHL pH Probe is a high-precision, lab-grade sensor designed for continuous monitoring of aquarium pH. Built for use with GHL ProfiLux controllers, it ensures stable, accurate readings in freshwater and marine systems. Its long cable and BNC connector make installation simple in sumps or return chambers, while galvanic isolation prevents interference and ensures reliable automation.
Key Features
Lab-grade pH electrode for accurate water chemistry monitoring
Long 3 m cable with BNC connector for flexible placement
Galvanically isolated for stable and interference-free readings
Durable for long-term immersion in freshwater and marine tanks
Compatible with GHL ProfiLux controllers and expansion modules
Benefits✔ Provides continuous, real-time pH monitoring✔ Integrates seamlessly with GHL automation for dosing, alarms, and control✔ Reduces manual testing, saving time and effort✔ Durable construction ensures long-term reliability✔ Ideal for reef, marine, and advanced freshwater aquariums
How to Use
Connect the probe to a compatible pH input on your GHL controller or expansion module.
Position the probe in a steady-flow area of your sump or return chamber.
Calibrate the probe using standard pH calibration solutions (pH 4, 7, 9) before first use.
Monitor readings through your controller interface or GHL app.
Maintain regularly by recalibrating and cleaning the probe to ensure long-term accuracy.
GHL Contactless Optical Level Sensor
DescriptionThe GHL Contactless Optical Level Sensor is a point‑level water sensor designed to work with GHL ProfiLux controllers to detect water levels through the aquarium or sump wall without any parts touching the water. This makes it ideal for applications like Auto Top‑Off (ATO) and leak detection where you want reliable detection but minimal components in the water.
Key Features
Detects water level through glass or clear acrylic without contact
Fits standard GHL level sensor ports on ProfiLux controllers
No moving parts — low maintenance and corrosion‑free
Simple stick‑on installation on the outside of a tank or reservoir
Compatible with ATO and leak detection routines on GHL systems
Benefits✔ Non‑contact water level sensing protects the sensor from corrosion and buildup✔ Easy to install on the outside of your aquarium or sump✔ Works with GHL automation for automatic top‑off and alarms✔ No electrodes or probes inside the water to worry about✔ Great for maintaining stable water levels and avoiding spills
How to Use
Clean and dry the outside surface of your aquarium, sump, or reservoir glass.
Stick the sensor on the outside at the height where you want level detection.
Connect the sensor to a level port on your GHL ProfiLux controller via the cable.
Configure the sensor function in the GHL software (e.g., min level for ATO or leak detection).
Monitor status via controller display/app and adjust placement if needed for best performance.
Notes & Tips
These sensors work by detecting the change in refractive index when water touches the outside of the glass, so glass with heavy tint or metal content may affect detection.
They are best suited for ATO and leak detection but aren’t recommended for automatic water change applications where the glass might remain wet above water level, leading to false triggers.
GHL Conductivity Probe
DescriptionThe GHL Conductivity Probe is a professional‑grade sensor designed to measure water conductivity — an electrical measurement used to determine salinity and dissolved ion concentration in aquarium water. When connected to a compatible GHL ProfiLux controller system, the probe continuously provides accurate data that helps you monitor and manage crucial water quality parameters for saltwater and reef aquariums.
Key Features
High‑precision conductivity electrode for aquarium environments
Platinum sensor element optimized for durability and corrosion resistance
Long connection cable (typically around 3 m) with secure BNC connector
Designed to work with ProfiLux controller inputs and conductivity expansion modules
Measures conductivity values which are used (with temperature compensation) to estimate salinity/density in marine tanks
Benefits✔ Continuous real‑time monitoring of conductivity/salinity✔ Helps you maintain consistent salt levels and water chemistry✔ Enables automated alerts and actions via your ProfiLux controller✔ Built to laboratory‑grade quality standards for reliability ✔ Durable for long‑term aquarium use
How to Use
Install the probe in your sump or return chamber at a stable flow location.
Connect the BNC cable to the conductivity input on your ProfiLux controller or expansion card.
Calibrate the sensor using standard calibration solutions (e.g., 1.41 mS for freshwater / 50 mS for saltwater) and the controller’s guided calibration menu.
Temperature compensate the readings using a connected temperature probe for accurate salinity values.
Monitor values via your controller display or app, and set alarms or automation rules based on thresholds.
GHL Powerbar 5.1D‑PAB – Intelligent Power Management for ProfiLux Aquarium Systems
DescriptionThe GHL Powerbar 5.1D‑PAB is a specialised power distribution unit designed to integrate seamlessly with GHL ProfiLux aquarium controllers via the ProfiLux Aquatic Bus (PAB). It provides reliable, automated control of multiple electrical devices in your aquarium setup — like lights, pumps, chillers, heaters and more — while giving you advanced safety and automation features.
Key Features
Five independently switchable 230 V sockets plus one dimmable socket
Connects to your ProfiLux controller via two PAB ports for robust communication
Uses industrial high‑inrush current (HIC) relays for safe switching of high‑load devices
Individual LED status indicators for each socket plus a system status display
Individual fuses per socket and main fused switch for protection
Fail‑safe mode: Program each outlet’s behaviour in case of loss of communication with the controller
Compact design with mounting brackets for organised installation
Benefits✔ Automates equipment control — your ProfiLux controller can turn devices on/off based on conditions like time, sensors or alarms. ✔ Handles high loads safely — industrial relays mean reliable switching even for chillers or large pumps. ✔ Improved safety — fuses and visual indicators help protect against overload and provide easy troubleshooting. ✔ Dimmable output option — perfect for variable‑speed pumps or lighting that require finer control. ✔ Expandable system — with PAB integration, you can daisy‑chain multiple Powerbars or devices for larger setups.
How to Use
Mount the Powerbar in your aquarium cabinet or rack.
Connect the PAB cable(s) from your GHL ProfiLux controller to the Powerbar’s PAB ports.
Plug your aquarium devices (lights, pumps, heaters, etc.) into the appropriate sockets.
Configure each socket’s assignment and behaviour using GHL Connect or GHL Control Center.
Set fail‑safe states for each socket (e.g., heater off if communication is lost).
Monitor and adjust settings remotely via the app or software as needed.
GHL Module pH & Redox – Expansion Card for ProfiLux Controllers
DescriptionThis GHL pH & Redox (ORP) expansion module is an official sensor interface card that adds dedicated measurement inputs to your GHL ProfiLux aquarium controller or Expansion Box. It provides a galvanically isolated input that can be switched between a pH probe or a Redox (ORP) probe, allowing your system to monitor crucial water chemistry parameters with high precision.
Key Features
Internal expansion card for GHL ProfiLux controllers / Expansion Box
One galvanically isolated input for a pH sensor or Redox (ORP) sensor
Designed for accurate chemical measurements without electrical interference
Easy installation into an available expansion slot
Automatically recognized by the ProfiLux system once installed
Benefits✔ Monitors critical pH or Redox levels in real time✔ Improves control over aquarium water chemistry✔ Reduces the need for manual testing with handheld meters✔ Integrates directly with GHL automation and alarm functions✔ Enhances advanced reef, marine and freshwater monitoring setups
How to Use
Power down your GHL controller or Expansion Box.
Insert the module into an open expansion card slot.
Connect either a pH or Redox (ORP) probe to the input.
Power on the system and let it detect the new module.
Calibrate the sensor via GHL Connect or controller interface.
Set acceptable parameter ranges and automation responses as needed.
GHL pH/Redox‑Dig Temperature Module – Expansion Card for ProfiLux Controllers
DescriptionThe GHL pH/Redox‑DigTemp Module is an expansion card designed to add extra sensor capabilities to your ProfiLux aquarium controller or Expansion Box. It provides dedicated inputs so you can monitor water chemistry and temperature with high precision — essential for reef and advanced freshwater environments.
Key Features
Adds one switchable input for either a pH sensor or a Redox (ORP) sensor
Includes one dedicated input for a digital water temperature sensor
All sensor inputs are galvanically isolated to prevent electrical interference and improve measurement accuracy
Plugs directly into an available expansion slot on compatible GHL controllers or the Expansion Box
Benefits✔ Expands your controller’s monitoring capabilities✔ Lets you track and automate based on both pH/ORP and temperature readings✔ Improves water chemistry stability and control✔ Reduces the need for manual testing with handheld meters✔ Allows more precise automation and alarms for water quality adjustments
How to Use
Turn off your controller and unplug it from mains power.
Insert the module into a free expansion slot on your ProfiLux controller or Expansion Box.
Connect a pH or Redox probe to the switchable input.
Connect a digital water temperature sensor to the dedicated temp port.
Power up the system.
Calibrate sensors and configure monitoring/dosing rules via GHL software or app.
GHL Module Level – Level Expansion Module for GHL ProfiLux
DescriptionThe GHL Module Level is an expansion accessory for the GHL ProfiLux aquarium controller ecosystem. It adds additional level sensor inputs to your controller or expansion box, allowing you to connect more water level sensors — such as float or optical level probes — for advanced functions like auto top‑off (ATO), automatic water changes (AWC) and leak detection.
Key Features
Provides extra level sensor input ports for GHL controllers
Works with GHL level sensors (optical or float)
Plug‑and‑play installation into expansion slots
Ideal for sums, reservoirs and multiple water level zones
Enables more robust automation and safety features
Benefits✔ Expands water level monitoring capability beyond built‑in ports✔ Helps automate ATO and water change sequences✔ Improves safety via additional leak or overflow detection✔ Makes complex multi‑tank setups easier to manage✔ Seamless integration with ProfiLux system and interface
How to Use
Install the Module Level card into an available expansion slot on your ProfiLux controller or expansion box.
Connect your additional level sensors (float or optical) to the new ports.
Calibrate sensors via the GHL Connect app or controller interface.
Assign sensor functions (ATO, AWC or leak detection) in your system settings.
Monitor and automate responses based on level changes.
GHL Conductivity (Saltwater) & pH Combo Module – Sensor Expansion for GHL Aquarium Controllers
DescriptionThe GHL Conductivity (Saltwater) & pH Combo Module is an expansion accessory for your GHL ProfiLux controller system that adds dedicated sensor inputs for measuring saltwater conductivity (salinity) and pH in your aquarium. These vital measurements help you continuously monitor key water quality indicators and automate responses when values go outside safe ranges.
Key Features
Dual inputs for conductivity (saltwater) and pH sensors
Designed to plug into available expansion slots on compatible GHL controllers
Uses galvanically isolated inputs to avoid electrical interference
Works with high‑quality GHL sensors for accurate, reliable measurement
Supports automated monitoring and control via the ProfiLux system
Ideal for marine and reef aquariums where salinity and pH stability are critical
Benefits✔ Enables continuous, real‑time monitoring of salinity and pH✔ Helps you maintain stable water chemistry for fish and coral health✔ Integrates seamlessly with automation and alarms on ProfiLux controllers✔ Avoids the need for manual testing with handheld meters✔ Makes your GHL system more capable and responsive
How to Use
Install the combo module into a free expansion slot on your GHL controller.
Connect a conductivity probe and a pH probe to the module.
Calibrate each sensor using GHL’s software (Control Center or Connect).
Set desired salinity and pH ranges in your controller settings.
Monitor readings remotely and let the system automate alerts or corrective actions if needed.
GHL Touch – ProfiLux
DescriptionThe GHL Touch Display is an intuitive 4.3″ color touchscreen accessory designed to extend and enhance control of your GHL ProfiLux aquarium controller system. It connects via the ProfiLux Aquatic Bus and puts real‑time monitoring and direct control right at your fingertips. With clear graphical display and one‑touch access to key functions, it lets you interact with your tank’s automation without needing a smartphone or PC.
Key Features
Large 4.3″ color touch display for easy viewing and control
Shows live data like temperature, pH, ORP, conductivity, oxygen and more
Access special modes like feeding, maintenance or water change with a single touch
Manual control of outlets and lighting settings
Built‑in data logging with millions of readable values
Compatible with GHL ProfiLux 3 and newer controllers (including ProfiLux 4)
Benefits✔ Local, convenient access to aquarium status without another device ✔ See key parameters and trends at a glance ✔ Quick touch control for common tasks like feeding pauses ✔ Makes interacting with your ProfiLux system easier and faster ✔ Great for aquarists who want a dedicated, mounted control interface
How to Use
Mount or position the Touch Display near your aquarium or controller.
Connect it to your ProfiLux controller via the ProfiLux Aquatic Bus (PAB) port.
Power on the unit and let it sync with your controller.
Navigate parameters, graphs and quick‑access functions using the touchscreen.
Use on‑screen shortcuts for feeding pause, maintenance modes, lighting or alarms.
GHL Level/Temp Extension Cable – 2 m & 5 m
DescriptionThe GHL Level/Temp Extension Cable is a genuine GHL accessory designed to extend the reach of your level and temperature sensors (such as optical level, float level, or temperature probes) when using a GHL ProfiLux controller system. It allows you to position sensors farther from the controller — ideal for larger aquariums, remote sumps, or technical cabinets — while maintaining accurate, reliable signal transmission. These cables are available in both 2 m and 5 m lengths to suit different installation needs.
Key Features
Official GHL extension cable for level & temp sensors (PS/2 style)
Available in 2 m and 5 m lengths
Plugs directly between the sensor and controller
Maintains accurate sensor readings over distance
Simple plug‑and‑play installation
Benefits✔ Extends sensor reach for flexible placement✔ Ideal for large tanks, remote cabinets or sumps✔ Preserves accurate data without signal loss✔ Makes sensor positioning cleaner and neater✔ Works seamlessly with GHL ProfiLux controllers
How to Use
Unplug the original sensor cable from your GHL controller.
Plug the extension cable into the sensor’s connector.
Plug the other end of the extension into the controller.
Arrange the sensor in your tank, sump, or reservoir at the desired position.
Power the system and verify the sensor is reporting correctly.
GHL Float Bracket/Fastener
DescriptionThe GHL bracket float is an accessory used to mount a GHL float (level) sensor securely in your aquarium, reservoir, or sump when setting up automatic water level functions with a GHL ProfiLux controller. It holds the mechanical float switch in the correct position so it can accurately detect water level changes for top‑off, water changes or leak detection.
Key Features
Designed to work specifically with GHL float sensors used in ProfiLux setups
Provides stable and adjustable mounting for the float switch
Ensures accurate detection of water level when combined with a sensor
Helps integrate float sensors into sump, reservoir or tank installations
Benefits✔ Keeps the float sensor properly positioned✔ Improves reliability of water level detection✔ Makes setup for ATO or automatic water change easier✔ Works with ProiLux controller automation functions
Typical UseYou’d attach the GHL float switch to this bracket (often along with a sensor holder base like PL‑LF‑Base2) and set the float at the height where the controller should detect low or high water. The controller will then react (start/stop pumps or trigger alerts) based on the float’s position.
GHL Doser 2.1 4‑Pump Dosing System
DescriptionThe GHL Doser 2.1 with 4 dosing pumps is a high‑precision aquarium dosing system designed for hobbyists and professionals to automate the delivery of trace elements, fertilizers, balling solutions, kalkwasser and other liquids. It combines four independently programmable pumps with modern connectivity options so you can schedule and manage dosing from your smartphone, tablet, or PC.
Key Features
Four independent 24 V stepper‑motor dosing pumps with chemical‑resistant tubing for durability and accuracy
Highly precise dosing with micro‑increments down to ~0.1 mL
Up to 150 doses per day with flexible scheduling via software
Wi‑Fi, USB and LAN connectivity for remote configuration and monitoring
LED status indicator displays system health and alerts
Can be used as a standalone unit or integrated into a GHL ProfiLux controller system
Expandable to up to 16 pumps with additional modules via the ProfiLux Aquatic Bus (PAB)
Benefits✔ Automates dosing so you don’t have to manually measure and add liquids throughout the week ✔ Improves water chemistry stability for healthier fish, corals and plants ✔ Precision control reduces risk of overdosing or under‑dosing ✔ Remote management lets you adjust schedules from anywhere ✔ Expandable system grows with your aquarium needs
How to Use
Place dosing containers near your aquarium or sump.
Connect each pump’s tubing to the respective liquid reservoir.
Plug the unit into power and optionally connect to Wi‑Fi/USB/LAN.
Use the GHL Control software or app to set dosis amounts and schedules.
Monitor dosing status and tank parameters remotely.
Refill reservoirs when low and recalibrate as needed.